LABS conformity tests according to the standard VDMA Sheet 24364
The following steps are required for the LABS conformity test in accordance with standard VDMA Sheet 24364:
- select the product group and test class.
- perform zero test.
- perform the test, evaluate it and document it.
When selecting the product group and test class, both the intended use of the product and the zone classification described above are helpful. The test class is then selected depending on the load when used as intended. Before the actual test, the zero test is essential. This ensures that all testing and work equipment used as well as the work environment itself are LABS-compliant. Otherwise, it cannot be reliably assessed whether any errors are due to the work environment or the test object itself. A zero test can be, for example, to subject the test document to the planned test once.
Subsequently, the actual test is performed. The test specimen is placed on the test document where the test takes place. This can be, for example, the rinsing of the test specimen with solvent. Wait until the solvent has completely evaporated and then carry out the paint process. In the cured state, the paint film is then evaluated. The evaluation consists of a visual inspection without additional aids. Either LABS-compliant or non-LABS-compliant can be considered as a result. Quantification is not the objective of this type of test. It is also important to note that there are LABS-dependent and LABS-independent error patterns, e.g., craters have appeared, but the surface was completely wetted with paint. In this case, the product would still be LABS-compliant.