Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Components | Body | Rod | Cover | Shaft | Ball Bushing |
Material | Aluminum | Steel | ABS | Steel | Steel |
Surface Treatment | Acrylic Paint | - | - | - | - |
Accessory | Controller I/O Specifications | ||
NPN, PNP | CC-Link | DeviceNet | |
Instruction Manual (CD-ROM), Power Connector, Dummy Connector, 6 Mounting Nuts | |||
- | CC-Link Connector | DeviceNet Connector |
Part Number | - | Motor Mounting Direction | - | Controller | - | I/O Module | - | Cable Length | - | Stroke | |
RSD306B | - | U |
- | C1 | - | N | - | 3 | - | 200 | (Motor Mounting Direction: U) |
RSD306B | - | C1 | - | N | - | 3 | - | 200 | (Motor Mounting Direction: Straight) | ||
RSD306B | - | U |
- | P1 | - | 3 | - | 200 | (Motor Mounting Direction: U, Controller: P1) |
Ball Screw | Motor | Position Detector | Operating Ambient Temperature, Humidity |
Ø12 (C10 Rolled) |
Stepping | Resolver (Incremental) |
0~40°C, 35~85%RH (No Condensation) |
Type | Lead (mm) | Repeatability Positioning Accuracy (mm) |
Max Load Capacity (kg) | Max. Push Force (N) |
Rated Running Life 1 |
Lost Motion (mm) | Rod Non-Rotational Accuracy (degrees) | Stroke (mm) | Max. Velocity 2 (mm/sec) |
Input Power Supply | Maximum Positioning Point | |
Horizontal | Vertical | |||||||||||
RSDG3 | 02 | ±0.02 | 60 | 28.5 | 900 | 5,000km or More | 0.1 or Less | ±0.05 | 50~300 (50 Pitch) |
~50 | DC24V ±10% |
255 points |
06 | 55 | 18.5 | 550 | ~150 | ||||||||
12 | 50 | 8.5 | 250 | ~300 |
Type | Dimensions / Mass | Motor Mounting Direction: Straight | Motor Mounting Direction: U | ||||||||||
Stroke (mm) | Stroke (mm) | ||||||||||||
50 | 100 | 150 | 200 | 250 | 300 | 50 | 100 | 150 | 200 | 250 | 300 | ||
RSDG3 | L1 (mm) | 183 | 223 | 283 | 333 | 383 | 433 | 183 | 223 | 283 | 333 | 383 | 433 |
L (mm) | 280.5 | 330.5 | 380.5 | 430.5 | 480.5 | 530.5 | 227.5 | 277.5 | 327.5 | 377.5 | 427.5 | 477.5 | |
Mass (kg) | 3.1 | 3.6 | 4.1 | 4.5 | 5 | 5.5 | 3.3 | 3.8 | 4.3 | 4.7 | 5.2 | 5.7 |
Part Number | Selection | ||||||
Type | Lead (mm) | With or w/o Brake ( 1) | Motor Mounting Direction | Controller ( 2) | I/O Module | Cable Length (m) | Stroke (mm) |
RSDG3 | 02 | None: Leave blank Included: B |
Straight: Leave blank Top mounting: U |
Point Control: C1 Pulse Control: P1 (DC24V ±10%) |
NPN: N PNP: P CC-Link: C DeviceNet: D |
1 3 5 10 (Flexible Cable) |
50~300 (50mm Increment) |
06 | |||||||
12 |
3D preview is not available, because the part number has not yet been determined.
Part Number | Minimum order quantity | Volume Discount | Stroke (mm) | Max. Transportable Mass Range (Horizontal) (kg) | Max. Transportable Mass (Horizontal) (kg) | Max. Transportable Mass Range (Vertical) (kg) | Max. Transportable Mass (Vertical) (kg) | Lead (mm) | I/O Module | Brake | Max. Thrust Force Range (N) | Max. Push Force (N) | Environmental Spec. | Maximum Velocity (mm/sec) | Controller Type | Motor Mounting Direction | #5 | #6 | Cable Length (m) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | NPN / PNP / CC-Link / DeviceNet | Not Provided | 501 to 1000 | 900 | - | 50 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | - | 50 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | Standard Specification | 50 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | Standard Specification | 50 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | NPN / PNP / CC-Link / DeviceNet | Provided | 501 to 1000 | 900 | - | 50 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | - | 50 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | Standard Specification | 50 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 60 | 20.1 to 50.0 | 28.5 | 2 | - | Not Provided | 501 to 1000 | 900 | Standard Specification | 50 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | NPN / PNP / CC-Link / DeviceNet | Not Provided | 501 to 1000 | 550 | - | 150 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | - | 150 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | Standard Specification | 150 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | Standard Specification | 150 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | NPN / PNP / CC-Link / DeviceNet | Provided | 501 to 1000 | 550 | - | 150 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | - | 150 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | Standard Specification | 150 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 50.1 to 100.0 | 55 | 10.1 to 20.0 | 18.5 | 6 | - | Not Provided | 501 to 1000 | 550 | Standard Specification | 150 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | NPN / PNP / CC-Link / DeviceNet | Not Provided | 201 to 300 | 250 | - | 300 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | - | 300 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | Standard Specification | 300 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | Standard Specification | 300 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | NPN / PNP / CC-Link / DeviceNet | Provided | 201 to 300 | 250 | - | 300 | Point Control (C1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | - | 300 | Pulse Train Control (P1) | Straight | - | - | 1 ~ 10 | ||
1 | 14 Days | - | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | Standard Specification | 300 | Point Control (C1) | Top Half | 1 ~ 10 | 50 ~ 300 | - | ||
1 | 14 Days | 50 ~ 300 | 20.1 to 50.0 | 50 | 5.1 to 10.0 | 8.5 | 12 | - | Not Provided | 201 to 300 | 250 | Standard Specification | 300 | Pulse Train Control (P1) | Top Half | - | - | 1 ~ 10 |
Loading...
Main Body, Peripheral Components | Main Body | Type | Rods | Drive Method | Rolled Ball Screw |
---|---|---|---|---|---|
Guide | Provided | Input Power Supply | 24 V DC | Position Detector | Resolver, Incremental Type |
Positioning Repeatability(µm) | ±20 | Operating Ambient Temperature(°C) | 0::40 |
Configure
Basic Attributes
Stroke(mm)
Max. Transportable Mass Range (Horizontal)(kg)
Max. Transportable Mass (Horizontal)(kg)
Max. Transportable Mass Range (Vertical)(kg)
Max. Transportable Mass (Vertical)(kg)
Lead(mm)
I/O Module
Brake
Max. Thrust Force Range(N)
Max. Push Force(N)
Environmental Spec.
Maximum Velocity(mm/sec)
Controller Type
Motor Mounting Direction
#5
#6
Cable Length(m)
Type
Filter by CAD data type
Filter by standard shipping days
Optional Attributes