Frequency Inverter [SX] (Part Numbers)

Frequency Inverter [SX]
Force & flow in perfect harmony
Designed to drive high power functionality
• 400V and 690V power supply from 0.75 kW up to 1,400 kW
• New operator with Real-Time Clock
• Optional control panel with Bluetooth
• PM motor control
• Compact design IP20 & IP54 full range
• Built-in Filter according to C3 Class and fuses from 220 kW
• Safety EN62061 standards STO SIL2
• Load curve control
• Logic programmability
• Built-in special application functionality as Multi-pump control or Crane applications
• Hardware customisation (Main switch, Liquid cooling, 12-pulse rectifier, … )
• Fieldbus communications: EtherCAT, PROFINET, Modbus, DeviceNet, PROFIBUS, Modbus TCP

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
SX-D6075-EVA4
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Voltage class
(V)
Max. output at linear load at rated output voltage
(kW)
Max. output at quadratic load at rated output voltage
(kW)
Nominal output current I2N
(A)
Mains voltage
(V)
Max. output voltage
(V)
Degree of protection

26,480.00 €

1 3 Days 1090345312AC690557582500 - 690690NEMA Other, IP54

Loading...

Basic information

Output Specification Three-Phase Mains frequency(Hz) 50/60 Hz Max. output frequency(Hz) 400
Number of analogue outputs 2 Number of analogue inputs 4 Number of digital outputs 5
Number of digital inputs 8 Number of HW-interfaces industrial Ethernet 0 Number of HW-interfaces USB 0
Number of HW-interfaces RS-485 0 Number of HW-interfaces RS-422 0 Number of HW-interfaces other 3
Number of interfaces PROFINET 0 Number of HW-interfaces parallel 0 Number of HW-interfaces serial TTY 0
Number of HW-interfaces RS-232 0 Supporting protocol for DeviceNet true Supporting protocol for CAN false
Supporting protocol for PROFINET IO true Supporting protocol for TCP/IP true Supporting protocol for Modbus true
Supporting protocol for DeviceNet Safety false Supporting protocol for EtherNet/IP true Supporting protocol for PROFIBUS true
Supporting protocol for other bus systems true Application in domestic- and commercial area permitted true With optical interface false
Integrated breaking resistance false Application in industrial area permitted true Supporting protocol for INTERBUS-Safety false
Supporting protocol for KNX false Supporting protocol for PROFINET CBA false Supporting protocol for SafetyBUS p false
Supporting protocol for SUCONET false Supporting protocol for INTERBUS false Supporting protocol for Data-Highway false
Supporting protocol for PROFIsafe false Supporting protocol for Foundation Fieldbus false Supporting protocol for SERCOS false
Supporting protocol for LON false Supporting protocol for ASI false Supporting protocol for AS-Interface Safety at Work false

Tech Support