Guard Lock Safety-door Switch [D4SL-N] (Part Numbers)

Guard Lock Safety-door Switch [D4SL-N]
Varied lineup of Guard Lock Safety-door Switches
• Wiring time is reduced with two types of wiring methods capable of one-touch attachment and removal.
• A wide variety of built-in switches can be used for various devices. (4-, 5-, and 6-contact models are available)
• Key holding force of 1,300 N.
• It is possible to change the operation key insertion point without detaching the head.
• Drive solenoids directly from the Controller.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
D4SL-N4CFG
D4SL-N4EDA-D
D4SL-N4NFG-D
D4SL-N4RDA-DN
D4SL-N4RFA-D
D4SL-N4RFG-D
D4SL-N4VFA
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Main Body External Shape Depth D
(mm)
Housing Material With Status Indication Number of Contacts as Normally Closed Contact Rated Operation Current Ie at DC-13, 24 V
(A)
Number of Contacts as Normally Open Contact Rated Operation Current Ie at AC-15, 230 V
(A)
Type of Switching Contact Rated Operation Current Ie at AC-15, 24 V
(A)
Rated Operation Current Ie at DC-13, 230 V
(A)
Type of Guard Locking

197.60 €

1 3 Days 155Otherfalse3-1-Other--Operating current principle

230.40 €

1 3 Days 179.9Plastictrue3-2-----

214.80 €

1 3 Days 179.9Plastictrue4-2-----

230.40 €

1 3 Days 155Othertrue6000Slow-action switch00Operating current principle

214.80 €

1 3 Days 179.9Plastictrue6-0-----

214.80 €

1 3 Days 179.9Plastictrue6-0-----

197.60 €

1 3 Days 155Otherfalse4-0-Other--Quiescent current principle

Loading...

  1. 1

Basic information

Operating Temperature Range(°C) -10::55 Protective Structure IP67 Main Body External Shape Width W(mm) 39
Main Body External Shape Height H(mm) 39 Degree of Protection (NEMA) 4X Type of Electric Connection Cable entry metrical
Coating Housing Other Construction Type Housing Cuboid Number of Contacts as Change-Over Contact 0
Number of Safety Auxiliary Contacts 0 Rated Operation Current Ie at AC-15, 125 V(A) 1.5 Rated Operation Current Ie at DC-13, 125 V(A) 0.22
With Escape Release true Guard Locking Force(N) 1300 Rated Control Supply Voltage Magnet Drive DC(V) 20.4 - 26.4
With Auxiliary Release true Suitable for Safety Functions true

Tech Support